Article Detail
Return to Search Results
Article ID
Title
URL https://www.ncbi.nlm.nih.gov/pubmed/8263431
Journal J Manipulative Physiol Ther. 1993 Oct;16(8):523-526
Author(s)
Peer Review Yes
Publication Type Article
Abstract/Notes

OBJECTIVE: The purpose of this study was to confirm a practitioner's perception of cavitation during spinal manipulative therapy in a clinically relevant situation using accelerometer recordings.

DESIGN: Experimental study.

SETTING: Human Performance Laboratory and Sports Medicine Center, University of Calgary.

PARTICIPANTS: Twenty-eight patients from a single practitioner's patient pool who had pain in the area of the thoracic spine.

INTERVENTION: Spinal manipulative treatment (SMT) on the transverse process of T4 using a reinforced unilateral contact and delivering a thrust in the posterior to anterior direction.

MAIN OUTCOME MEASURES: Instantaneous acceleration signals obtained from the spinous process of T3 during SMT and the practitioner's perception if cavitation had occurred or not at the end of each treatment.

CONCLUSIONS: It appears that cavitation may be measured during SMT using accelerometry and that a practitioner's perception of the occurrence of cavitation during SMT is very accurate.

This abstract is reproduced with the permission of the publisher. Article only available in print.


 

Subject(s)