  Title Validity and diagnostic accuracy of using a smartphone for the measurement of the angle of trunk rotation and the stiffness scoliosis test in adolescents with scoliosis
URL https://doi.org/10.1016/j.jcm.2025.09.022
Journal J Chiropr Med. 2025 ;24(1-4):226-231
Author(s)
Subject(s)
Peer Review Yes
Publication Type Article
Abstract/Notes

Objective: The purpose of this study was to determine the validity and diagnostic accuracy of the angle of trunk rotation (ATR) and the stiffness scoliosis test (SST) measured using a smartphone with a simple external device (binder clips) using the scoliometer as the reference standard; and (2) to evaluate the effect of the rater’s experience.  

Methods: This was a diagnostic accuracy study. Each participant was evaluated by 2 raters using a scoliometer and a smartphone (applied using a very simple external device - binder clips). Exclusion criteria: spinal surgery, any diagnosable cause of scoliosis, and upper or lower limb amputation. The sequence of the 2 consecutive procedures of evaluation and the 2 raters were randomly chosen. For statistical purposes, the Spearman’s and Pearson’s correlation test, the root mean square (RMS) error, the Bland-Altman graphic analysis and the ROC curve analysis were conducted (P < .05).

Results: The sample consisted of 50 gibbosities of 38 participants, where 74% (n = 28) were girls and 26% (n = 10) boys, with a mean age of 13.4 ± 2.5 years. The correlations were excellent, ranging from 0.77 to 0.91 for ATR and SST, with RMS error of 2° to 5°. There was agreement between the measurements with a mean difference of 0.04° to 1.24°. The ROC curve presented an area under the curve of 95%.

Conclusion: The smartphone, when used with a simple external device (binder clips), is valid and accurate for ATR and SST measurement. Evaluator experience has no effect on the results.

Author Keywords: Scoliosis; Accuracy; Validation Study; Diagnosis; Measurement Properties

This abstract is reproduced with the permission of the publisher; full text is available by subscription. Online access only.


 

   Text (Citation) Tagged (Export) Excel
 
Email To
Subject
 Message
Format
HTML Text     Excel



To use this feature you must register a personal account in My ICL. Registration is free! In My ICL you can save your ICL searches in My Searches, and you can save search results in My Collections. Be sure to use the Held Citations feature to collect citations from an entire search session. Read more search tips.

Sign Into Existing My ICL Account    |    Register A New My ICL Account
Search Tips
  • Enclose phrases in "quotation marks".  Examples: "low back pain", "evidence-based"
  • Retrieve all forms of a word with an "asterisk*", also called a wildcard or truncation.  Example: "chiropract*" retrieves chiropractic, chiropractor, chiropractors
  • Register an account in My ICL to save search histories (My Searches) and collections of records (My Collections)
Advanced Search Tips

:)